Reference Values for Serum Calcium in Neonates Should Be Established in a Population of Vitamin D–Replete Subjects
Résumé
Context Serum calcium is frequently measured during the neonatal period, and it is known to be influenced by the vitamin D status. Objective We hypothesized that the 25-hydroxyvitamin D (25OHD) concentration may influence the lower limit of the serum calcium normal range in neonates. Methods We included in our prospective cohort study 1002 mother-newborn pair recruited from April 2012 to July 2014, in 2 centers located in the neighborhoods of Paris, France, whose serum calcium was measured at 3 days of life. We established, after exclusion of outliers, a 95% CI for serum calcium (i) in our whole population of 1002 neonates; (ii) in neonates with a cord blood 25OHD concentration ≥ 30 nmol/L; and (iii) in those with a 25OHD ≥ 50 nmol/L. Results The mean serum total calcium was 2.46 ± 0.13 nmol/L (95% CI: 2.19-2.72 mmol/L), 2.47 ± 0.25 mmol/L (95% CI: 2.22-2.72 mmol/L), and 2.50 ± 0.25 mmol/L (95% CI: 2.25-2.75 mmol/L) in the whole group, in the 514 neonates with 25OHD ≥ 30 nmol/L, and in the 202 neonates with 25OHD ≥ 50 nmol/L respectively. The lower limit of the 95% range was significantly higher in neonates with 25 OHD ≥ 30 nmol/L (P < 0.05) and ≥ 50 nmol/L (P < .001) than in the entire cohort. Conclusion We show that the lower limit of the normal serum calcium range is higher in groups with a higher 25OHD than in unselected subjects. We propose that the reference range for serum calcium in neonates is 2.25 to 2.75 mmol/L.
Fichier principal
Manuscrit vitamin-D replete aVF R1 - 2024.03.01 clean.pdf (544.74 Ko)
Télécharger le fichier
Origine | Fichiers produits par l'(les) auteur(s) |
---|